High-Repeatable Data Acquisition Systems for Pulsed Power Converters.

Annotation

Saved in:
Bibliographic Details
Main Author: Arpaia, Pasquale
Other Authors: Baccigalupi, Carlo, Cerqueira Bastos, Miguel, Martino, Michelle
Format: eBook
Language:English
Published: New York : Momentum Press, 2017.
Subjects:
Online Access:Click for online access

MARC

LEADER 00000cam a2200000Mu 4500
001 on1007071758
003 OCoLC
005 20240809213013.0
006 m o d
007 cr |n|---|||||
008 171028s2017 nyu o 000 0 eng d
040 |a EBLCP  |b eng  |e pn  |c EBLCP  |d OCLCQ  |d IDEBK  |d MERUC  |d OCLCQ  |d S2H  |d OCLCO  |d OCLCF  |d OCLCQ  |d UX1  |d OCLCQ  |d OCLCO  |d OCLCQ  |d OCLCO  |d UEJ  |d OCLCQ 
020 |a 9781946646231 
020 |a 1946646237 
035 |a (OCoLC)1007071758 
050 4 |a TK2986  |b .A763 2017 
049 |a HCDD 
100 1 |a Arpaia, Pasquale. 
245 1 0 |a High-Repeatable Data Acquisition Systems for Pulsed Power Converters. 
260 |a New York :  |b Momentum Press,  |c 2017. 
300 |a 1 online resource (138 pages) 
336 |a text  |b txt  |2 rdacontent 
337 |a computer  |b c  |2 rdamedia 
338 |a online resource  |b cr  |2 rdacarrier 
588 0 |a Print version record. 
520 8 |a Annotation  |b This book addresses several issues related to the metrological characterization of high-performance pulsed power converters. Initially, a background and state-of-the-art on measurement systems for high-performance power converter are presented. In industrial applications of power converters metrology, specifications are often given in terms of worst-case uncertainty (WCU). Therefore, an analytical model for predicting the WCU of a measurement system is discussed and detailed for instruments affected by Gaussian noise. The authors discuss the study and design of a reference acquisition system for characterizing high-power pulses as well as the design of an on-line acquisition system for controlling the power converter. The book continues with numerical results obtained in simulation for the three main topics, which demonstrate the effectiveness of the proposals. Finally, the experimental results of a case study, carried out in the framework of the Compact Linear Collider (CLIC) at CERN, are reported. To meet CLIC requirements the two systems were designed to be ultra-low noise and are demonstrated to be repeatable in the order of few tens of parts per million (ppm). 
650 0 |a Analog-to-digital converters. 
650 0 |a Pulsed power systems. 
650 7 |a Analog-to-digital converters  |2 fast 
650 7 |a Pulsed power systems  |2 fast 
700 1 |a Baccigalupi, Carlo. 
700 1 |a Cerqueira Bastos, Miguel. 
700 1 |a Martino, Michelle. 
776 0 8 |i Print version:  |a Arpaia, Pasquale.  |t High-Repeatable Data Acquisition Systems for Pulsed Power Converters.  |d New York : Momentum Press, ©2017  |z 9781946646224 
856 4 0 |u https://ebookcentral.proquest.com/lib/holycrosscollege-ebooks/detail.action?docID=5105901  |y Click for online access 
903 |a EBC-AC 
994 |a 92  |b HCD