Double-pass optical quality analysis for the clinical practice of cataract / A-Yong Yu, editor.

This book introduces the principle, main parameters, acquisition mode and operation procedure of Optical Quality Analysis System II (OQAS II) based on double-pass technology. OQAS II is increasingly used in the diagnosis and assessment of ocular diseases, especially for cataract. In this book, the c...

Full description

Saved in:
Bibliographic Details
Other Authors: Yu, A-Yong (Editor)
Format: eBook
Language:English
Published: Singapore : Springer, 2021.
Subjects:
Online Access:Click for online access

MARC

LEADER 00000cam a2200000 a 4500
001 on1258674648
003 OCoLC
005 20240909213021.0
006 m o d
007 cr |n|||||||||
008 210702s2021 si o 000 0 eng d
040 |a YDX  |b eng  |e pn  |c YDX  |d GW5XE  |d EBLCP  |d OCLCO  |d OCLCF  |d DCT  |d UKAHL  |d OCLCO  |d OCLCQ  |d N$T  |d COM  |d FAU  |d CASUM  |d OCLCQ  |d OCLCO  |d OCLCL  |d DKU 
019 |a 1260343510  |a 1266814951  |a 1268574396 
020 |a 9789811604355  |q (electronic bk.) 
020 |a 9811604355  |q (electronic bk.) 
020 |z 9811604347 
020 |z 9789811604348 
024 7 |a 10.1007/978-981-16-0435-5  |2 doi 
035 |a (OCoLC)1258674648  |z (OCoLC)1260343510  |z (OCoLC)1266814951  |z (OCoLC)1268574396 
037 |b Springer 
050 4 |a RE451 
072 7 |a MED063000  |2 bisacsh 
072 7 |a MJQ  |2 bicssc 
072 7 |a MJQ  |2 thema 
049 |a HCDD 
245 0 0 |a Double-pass optical quality analysis for the clinical practice of cataract /  |c A-Yong Yu, editor. 
260 |a Singapore :  |b Springer,  |c 2021. 
300 |a 1 online resource 
336 |a text  |b txt  |2 rdacontent 
337 |a computer  |b c  |2 rdamedia 
338 |a online resource  |b cr  |2 rdacarrier 
347 |a text file 
347 |b PDF 
505 0 |a Visual quality in the age of refractive cataract surgery -- Analysis of objective visual quality based on Double-pass technology -- Clinical significance of the main parameters of Double-pass Optical Quality Analysis System -- Acquisition mode and operation procedure of Double-pass Optical Quality Analysis System -- Clinical application of objective evaluation of tear film optical quality -- Objective classification of cataract -- Timing of cataract surgery -- Prediction of the visual quality after cataract surgery -- Doctor-patient Communication -- Comparison of cataract treatment methods -- Optimal treatment timing for posterior capsule opacification. 
520 |a This book introduces the principle, main parameters, acquisition mode and operation procedure of Optical Quality Analysis System II (OQAS II) based on double-pass technology. OQAS II is increasingly used in the diagnosis and assessment of ocular diseases, especially for cataract. In this book, the clinical practice of OQAS II in the field of refractive cataract surgery is emphasized, including the preoperative/postoperative evaluation of visual quality, the timing of cataract surgery, the prediction of the visual quality after cataract surgery and doctor-patient communication. We hope the book provides a reference for the clinical application of the OQAS II in the field of cataract and helps to form the worldwide standard specification to a certain extent. 
588 0 |a Online resource; title from PDF title page (SpringerLink, viewed July 20, 2021). 
650 0 |a Cataract  |x Surgery. 
650 0 |a Crystalline lens  |x Diseases. 
650 7 |a Cataract  |x Surgery  |2 fast 
650 7 |a Cirurgia de cataractes.  |2 thub 
655 7 |a Llibres electrònics.  |2 thub 
700 1 |a Yu, A-Yong,  |e editor. 
758 |i has work:  |a Double-pass Optical Quality Analysis for the Clinical Practice of Cataract (Text)  |1 https://id.oclc.org/worldcat/entity/E39PD3PwXt3QF8t4mmKJmxpMfq  |4 https://id.oclc.org/worldcat/ontology/hasWork 
776 0 8 |i Print version:  |t Double-pass optical quality analysis for the clinical practice of cataract.  |d Singapore : Springer, 2021  |z 9811604347  |z 9789811604348  |w (OCoLC)1233166877 
856 4 0 |u https://holycross.idm.oclc.org/login?auth=cas&url=https://link.springer.com/10.1007/978-981-16-0435-5  |y Click for online access 
903 |a SPRING-MED2021 
994 |a 92  |b HCD